top of page

What Is a Scissor Truss, and When Do You Need One?

14 hours ago
5 min read

A scissor truss is a roof truss with a sloped bottom chord, so the ceiling below it rises toward the middle instead of sitting flat. You need one when you want a vaulted ceiling in a great room, bonus room or garage but still want factory-built trusses.

 

The catch is movement. The Structural Building Components Association (SBCA) says "The vertical loads applied to the scissor truss create a horizontal thrust at the bearing," and that thrust "may push out the wall if the truss is not allowed to slip." That is why the truss industry standard sets a default limit on how far a scissor truss can spread, and why the connection to the wall matters as much as the truss itself. This guide covers how scissor trusses move, the connectors and drawings they need, how much snow a roof carries and how to handle trusses on site.


CGR Wholesale Roofing

What Is a Scissor Truss?

 

Every truss has a top chord (the roof slope), a bottom chord (the ceiling line) and webs that tie the two together. In a standard truss, the bottom chord is flat. In a scissor truss, the bottom chord slopes up from each wall, so the members cross like an open pair of scissors and leave a vaulted ceiling below.

 

Trusses are engineered products. The IRC says the "design and manufacture of metal-plated wood Trusses shall comply with ANSI/TPI 1," the national standard from the Truss Plate Institute, as quoted by STRUCTURE magazine. Your truss maker designs each truss for your span, pitch and loads. CGR's guide to understanding trusses covers the basic types.

 

Do Scissor Trusses Push Out the Walls?

 

They can, if the bearing is not designed for it. SBCA explains that the thrust "may push out the wall if the truss is not allowed to slip or the wall is not stiff enough to offer resistance," and that "This horizontal movement translates into a vertical deflection, which is most visible at the ridgeline."

 

The standard sets limits. SBCA cites ANSI/TPI 1 section 7.6.3 for the horizontal limits and section 7.6.1 with IBC 1604.3 for the vertical limits:

 

Deflection

Limit cited by SBCA

Horizontal, total load

1-1/4 in

Horizontal, live load

3/4 in

Vertical, roof truss supporting drywall, total load

L/180 (span divided by 180)

Vertical, roof truss supporting drywall, live load

L/240

 

Source: SBCA, "Deflection Of Long Span Scissors Trusses," citing ANSI/TPI 1 and IBC 1604.3.

 

For a 35-foot truss, SBCA says that works out to "2 5/16" total load deflection and 1 3/4" live load deflection" vertically, and it notes that the building designer can specify more restrictive criteria. If the walls hold the truss in place instead, SBCA says the trusses "will need to be re-designed as pinned-pinned and checked for stress changes due to the horizontal thrust."

 

What Connections Do Scissor Trusses Need?

 

Simpson Strong-Tie's engineering blog says scissor trusses "must be designed with pin-roller bearings" in most cases. The alternative, it says, "isn't a valid option unless the walls are infinitely stiff (which they typically aren't)." In plain terms, one end is fixed and the other is allowed to slide.

 

To let that happen, Simpson points to slotted connectors "such as the slotted TC24 or TC26 connectors," which "allow for horizontal movement of the trusses without pushing out the wall, and also provide uplift resistance." Simpson notes they are "often used on alternating ends of the trusses" and that "The use of these clips also varies greatly by region."

 

Two rules follow:

 

  1. Ask the truss maker for the calculated horizontal movement. Simpson says, "It is important for the Building Designer to be aware of the calculated horizontal movement."

  2. Let the designer set the wall connection. SBCA says, "The building designer is responsible for designing the supporting structure and truss-to-wall connection accordingly."

 

What Should Be on the Truss Design Drawing?

 

The IRC requires truss design drawings, and STRUCTURE magazine's summary of the 2018 IRC lists what they must show, including:

 

  • "Slope or depth, span, and spacing"

  • "Reaction forces and required bearing widths"

  • "Top and bottom chord uniform and concentrated loads"

  • "Lumber size, species, and grade for each member"

  • "Calculated deflection ratio and/or maximum deflection for live and total load"

  • "Required permanent Truss member bracing locations"

 

In the version of R802.10.1 adopted in South Carolina, "Truss design drawings shall be provided with the shipment of trusses delivered to the job site," and drawings go to the building official. Pennsylvania enforces the IRC through its Uniform Construction Code, so confirm the local submittal steps with your code office. Keep the drawings on site; they tell the framer where the permanent bracing goes.

 

How Much Snow Can a Roof Hold?

 

It depends on the design load on the drawing, not on how deep the snow looks. FEMA's Snow Load Safety Guide gives these weights:

 

Load

Weight, per FEMA P-957

1 ft of fresh light, dry snow

3 lb per sq ft

1 ft of fresh wet, heavy snow

21 lb per sq ft

1 in of ice

A little under 5 lb per sq ft

1 ft of ice

About 57 lb per sq ft

 

FEMA also notes, "One foot of snow on the ground does not necessarily equal 1 foot of snow on a roof." Check the design snow load on the truss drawing or ask a licensed design professional for your site. Warning signs of overload, per FEMA, include "Popping, cracking, and creaking noises," "Sagging roof members," and "Doors and/or windows that can no longer be opened or closed." FEMA says roof snow removal "should be performed by a licensed, insured professional roofing contractor." CGR's post on roofing materials for heavy rain and snow covers the roof covering side.

 

How Should You Handle and Brace Trusses on Site?

 

BCSI, the SBCA and TPI's guide to truss handling and bracing list these handling and bracing rules:

 

  • "Using a single pick-point at the peak can damage the truss."

  • "NEVER use banding to lift a bundle."

  • "DO NOT store unbraced bundles upright."

  • "Do not walk on unbraced trusses."

  • "Lateral restraint is NOT adequate without diagonal bracing."

  • "DON'T stack materials on unbraced trusses."

  • "DO NOT cut, drill, relocate, add or remove any truss member" without the truss maker's instructions.

 

BCSI also says "Disregarding permanent restraint/bracing is a major cause of truss field performance" problems. CGR's guides on how trusses improve structural integrity and roof pitch help you plan the order.

 

FAQ

 

What is a scissor truss used for?

 

A scissor truss creates a vaulted ceiling. Its bottom chord slopes up from each wall instead of running flat.

 

Do scissor trusses push out walls?

 

They can. SBCA says the vertical load creates horizontal thrust at the bearing, which may push out the wall if the truss cannot slip or the wall is not stiff enough.

 

How much horizontal movement is allowed in a scissor truss?

 

SBCA, citing ANSI/TPI 1, says horizontal deflection is limited to 1-1/4 inches under total load and 3/4 inch under live load. Simpson Strong-Tie notes the building designer can set a stricter limit and that some scissor trusses are designed for more.

 

What connectors are used for scissor trusses?

 

Simpson Strong-Tie points to slotted connectors such as the TC24 or TC26, which allow horizontal movement and resist uplift.

 

How much does a foot of snow weigh on a roof?

 

FEMA puts 1 foot of fresh snow at 3 pounds per square foot for light, dry snow up to 21 pounds per square foot for wet, heavy snow.

 

Do trusses come with design drawings?

 

The IRC requires truss design drawings. South Carolina's adopted version says they ship with the trusses, so confirm Pennsylvania's submittal steps with your local code office.

 

Order Trusses at CGR Wholesale

 

CGR Wholesale Roofing & Siding Supply Center is "NOW STOCKING" trusses and beams from Montgomery Truss & Panel, which makes custom roof trusses, floor trusses and wall panels in Grove City, PA. Bring your building plans, span, roof pitch and the ceiling height you want to the Rostraver showroom, open Monday through Friday 7:00 AM to 4:00 PM and Saturday 7:00 AM to 12:00 PM, or call to ask whether a scissor design fits your plan.

 

Visit CGR Wholesale Roofing & Siding Supply Center or call 724-268-3671 today. Contact us for more information.


CGR Wholesale

 
 
 

Comments